Ccid commands, Ccid command pipe bulk-out messages, Pc_to_rdr_iccpoweron – ACS ACR1283L User Manual

Page 11

Advertising
background image

ACR1283L – Reference Manual

[email protected]

Version 1.00

www.acs.com.hk

Page 11 of 55

Offset

Field

Size

Value

Description

32

dwSynchProtocols

4

00000000h ACR1283L does not support

synchronous card.

36

dwMechanical

4

00000000h

ACR1283L does not support

special mechanical

characteristics.

40

dwFeatures

4

00040040h

ACR1283L supports the

following features:

Automatic parameters

negotiation made by the

CCID

Short and Extended APDU

level exchange with CCID

44

dwMaxCCIDMessageLength

4

0000020Ah

Maximum message length

accepted by ACR1283L is 522

bytes.

48

bClassGetResponse

1

00h

Indicates that the CCID echoes

the class of the APDU.

49

bClassEnvelope

1

00h

Indicates that the CCID echoes

the class of the APDU.

50

wLCDLayout

2

0000h

No LCD.

52

bPINSupport

1

00h

No PIN Verification.

53

bMaxCCIDBusySlots

1

01h

Only one slot can be

simultaneously busy.

5.2. CCID Commands

5.2.1.

CCID Command Pipe Bulk-OUT Messages

ACR1283L shall follow the CCID Bulk-OUT Messages as specified in CCID section 4. In addition, this

specification defines some extended commands for operating additional features. This section lists

the CCID Bulk-OUT Messages to be supported by ACR1283L.

5.2.1.1. PC_to_RDR_IccPowerOn

This command is used to activate the card slot and return ATR from the card.

Offset

Field

Size

Value

Description

0

bMessageType

1

62h

1

dwLength

4

00000000h Size of extra bytes of this message.

2

bSlot

1

Identifies the slot number for this command.

5

bSeq

1

Sequence number for command.

6

bPowerSelect

1

Voltage that is applied to the ICC.
00h = Automatic Voltage Selection
01h = 5 V
02h = 3 V

7

abRFU

2

Reserved for future use.