5.4.4.

Set Automatic PICC Polling

This command is used to set the reader’s polling mode.
Whenever the reader is connected to the PC, the PICC polling function will start the PICC scanning to

determine if a PICC is placed on/removed from the built-in antenna.
We can send a command to disable the PICC polling function. The command is sent through the

PC/SC Escape Command interface. To meet the energy saving requirement, special modes are

provided for turning off the antenna field whenever the PICC is inactive, or no PICC is found. The

reader will consume less current in power saving mode.

Set Automatic PICC Polling Format

Command

Class

INS

P1

P2

Lc

Data In

Set Automatic PICC Polling 0xE0h 0x00h 0x00h 0x23h 0x01h Polling Setting


Set Automatic PICC Polling Response Format

Response Class

INS

P1

P2

Le

Data Out

Result

0xE1h 0x00h 0x00h 0x00h 0x01h Polling Setting

Where:

Polling Setting:

Default value = 8Fh (1 Byte)

Polling Setting

Description

Description

Bit 0

Auto PICC Polling

1 = Enable

0 = Disable

Bit 1

Turn off Antenna Field if no PICC found

1 = Enable

0 = Disable

Bit 2

Turn off Antenna Field if the PICC is inactive

1 = Enable

0 = Disable

Bit 3

RFU

RFU

Bit 5 – 4

PICC Polling Interval for PICC

Bit 5 – Bit 4:

0 – 0 = 250 ms
0 – 1 = 500 ms

1 – 0 = 1000 ms
1 – 1 = 2500 ms

Bit 6

RFU

RFU

Bit 7

Enforce ISO14443A Part 4

1 = Enable

0 = Disable


Notes:

1. It is recommended to enable the option “Turn off Antenna Field is the PICC is inactive,” so

that the “Inactive PICC” will not be exposed to the field all the time so as to prevent the PICC

from “warming up.”

2. The longer the PICC Poll Interval, the more efficient of energy saving. However, the response