5.4.9.

Read Auto PPS

This command is used to check current auto PPS setting.


Read Auto PPS Format (5 Bytes)

Command

Class

INS

P1

P2

Lc

Read Auto

PPS

0xE0h

0x00h

0x00h 0x24h

0x00h


Set Auto PPS Response Format (9 Bytes)

Response Class

INS

P1

P2

Le

Data Out

Result

0xE1h 0x00h 0x00h 0x00h 0x02h

Max Speed

Current Speed

Where:

Max Speed (1 Byte):

Maximum Speed

Current Speed (1 Byte): Current Speed

Value can be: 106k bps = 0x00h (equal to No Auto PPS)

212k bps = 0x01h
424k bps = 0x02h (default setting)
848k bps = 0x03h