Page 14 of 55

Offset

Field

Size

Value

Description

1

dwLength

4

Size of extra bytes of this message.

5

bSlot

1

Identifies the slot number for this

command.

6

bSeq

1

Sequence number for command.

7

bProtocolNum

1

Specifies what protocol data structure

follows.
00h = Structure for protocol T=0
01h = Structure for protocol T=1
The following values are reserved for

future use:
80h = Structure for 2-wire protocol
81h = Structure for 3-wire protocol
82h = Structure for I2C protocol

8

abRFU

2

Reserved for future use.

10

abProtocolDataStructure Byte

array

Protocol Data Structure.


Protocol Data Structure for Protocol T=0 (dwLength=00000005h)

Offset

Field

Size

Value

Description

10

bmFindexDindex

1

B7-4 – FI – Index into the table 7 in ISO/IEC

7816-3:1997 selecting a clock rate conversion

factor
B3-0 – DI - Index into the table 8 in
ISO/IEC 7816-3:1997 selecting a baud rate

conversion factor

11

bmTCCKST0

1

B0 – 0b, B7-2 – 000000b
B1 – Convention used (b1=0 for direct, b1=1 for

inverse)

Note: The CCID ignores this bit.

12

bGuardTimeT0

1

Extra Guardtime between two characters. Add 0

to 254 etu to the normal guardtime of 12etu. FFh

is the same as 00h.

13

bWaitingIntegerT0

1

WI for T=0 used to define WWT

14

bClockStop

1

ICC Clock Stop Support.
00h = Stopping the Clock is not allowed
01h = Stop with Clock signal Low
02h = Stop with Clock signal High
03h = Stop with Clock either High or Low

Advertising