Fig. 23 – Actron AutoAnalyzer CP7665 User Manual

Page 22

Advertising
background image

22

manual for location of second-
ary ignition coil terminal.

• Verify BLACK test lead is con-

nected to primary ignition coil
negative (-) terminal.

13. View reading on display.

14. If vehicle is DIS, connect test

leads to terminals of the sec-
ondary ignition coil. Repeat
for remaining ignition coils.

15. Test Results - Secondary Coil

• Typical resistance range of

secondary ignition coils is
6.0k

- 30.0k

.

• R e f e r t o v e h i c l e s e r v i c e

manual for your vehicles re-
sistance range.

Fig. 23

Typical Cylindrical

Ignition Coil

Black

Red

Primary

Coil

Secondary

Coil

16. Repeat test procedure for a

HOT ignition coil.

NOTE: It is a good idea to test
ignition coils when they are both
hot and cold, because the resis-
tance of the coil could change
with temperature. This will also
help in diagnosing intermittent
ignition system problems.

17. Test Results - Overall

Good Ignition Coil:

Resistance

readings in Steps 10, 15 and 16
were within manufacturers speci-
fication.

Bad Ignition Coil:

Resistance

readings in Steps 10, 15 and 16
are not within manufacturers
specification.

Advertising