Recording -19, Recording – Actron AutoScanner® Plus CP9580A User Manual

Page 43

Advertising
background image

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 3 – 19

Using The Scan Tool

3

Recording

The

Recording function is used to play back a recording.

This function is very similar to

View Data. The only difference is that

View Data is real time viewing of PIDs, while Recording is a viewing

of previously recorded PIDs.

From the

Review Data menu:

1.Select

Recording.

•Use

UP or

DOWN

arrow key until

Recording is

highlighted.

2.

Select

Playback Recording.

The

Recording has frame

number and timestamp (in

seconds).

Negative frames and

timestamps indicate data

recorded before trigger event.

Positive frames and

timestamps indicate data

recorded after trigger event.

Use

UP or

DOWN

arrow keys to view recorded PID data

of each frame.

Use

LEFT

or

RIGHT arrow keys to scroll back and forth

through frames.

See Appendix A for PID Definitions.









=====================