Actron AutoScanner® Plus CP9580A User Manual

Page 86

Advertising
background image

Diagnostic Menu

4 – 30 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

4 4

The following O2 Sensor Tests are available:

1) Rich-to-lean sensor threshold voltage
2) Lean-to-rich sensor threshold voltage
3) Low sensor voltage for switch time
4) High sensor voltage for switch time
5) Rich-to-lean sensor switch time
6) Lean-to-rich sensor switch time
7) Minimum sensor voltage test cycle
8) Maximum sensor voltage test cycle
9) Time between sensor transitions
10) Sensor period
11) Manufacturer specific tests

From the Diagnostic Menu:

1. Select O2 Monitor Tests.

=====================

View Fre eze Data

Drive Cycle Monitor
O2 Monitor Tests
Diag Monitor Tests
On-Board Systems
Vehicle Information

Diagnostic Menu

O2 Monitor Tests

•Use

UP or

DOWN

arrow key until O2 Monitor
Tests
is highlighted.

•Press

ENTER.

=====================
O2 Bank1 Sensor1
O2 Bank1 Sensor2
O2 Bank2 Sensor1
O2 Bank2 Sensor2

Select O2 Sensor

O2 Bank1 Sensor1

2. Select O2 Sensor.

•Use

UP or

DOWN

arrow key until desired O2
Sensor is highlighted.

•Press

ENTER.

The O2 sensors located
upstream (before catalyst) may perform differently than ones located
downstream (after catalyst).

Test IDs are shown for unknown O2 sensor tests.

3. View Results of Selection.

Advertising