Data logging – ACU-RITE DRO 100 User Manual

Page 23

Advertising
background image

Troubleshooting

DRO 100

18

where measurements can again be displayed, selecting a lower display resolution,
or zeroing the display.

This error may also occur when using the automatic compensation routine while
setting the LEC parameter. An error indicates that the calculated compensation
factor was outside the acceptable range of -9999 to +9999, and usually is the
result of incorrectly entering data. Clear the error and return to the beginning of
the linear error compensation routine. Refer to page 8.

Data Logging

The readout collects information about itself while it is being used. This
information is stored in memory for review at a later time.

Press and hold the

RAD

DIA

key until the software version is displayed. Then press

the

SETUP

and

MM

keys simultaneously. Use the

ZERO

key to cycle through the

following information.

Power on time—displayed in decimal hours.

Scale travel distance—the travel distance for each axis is scrolled one after the
other.

Last 3 errors—the most recent three errors are remembered and messages for
the errors are scrolled one after the other.