ACU-RITE DRO 100 User Manual

Page 8

Advertising
background image

DRO 100

Introduction

3

Power-On Position Recovery

Position-Trac

Certain ACU-RITE encoders, such as the ENC 150, contain closely-spaced
reference marks that enable the display to show the correct position after a power
interruption. The readout will tell you when power has been lost, and will prompt
you to move each axis until a reference mark is located. By traversing the
reference marks once in each axis, you will re-establish the display position
relative to the last known zero. The most you will ever have to move an axis is
about one inch. You must move in the positive count direction. A flashing decimal
point indicates that the last position has not been recalled.

If you use an encoder without Position-Trac, the procedure for recovering your
position is slightly different. Reference marks on these encoders are about 8”
apart. You must find a convenient reference mark and then use the same mark
every time.

1.

Move near the desired reference mark.

2.

Press and hold the

ABS

INCR

key until the decimal point starts to flash.

3.

Move slowly past the reference mark until the readout recalls its position.
You must move in a positive direction.

Advertising