Appendix – American Magnetics 4Q06250PS-430 High Stability Integrated Power Supply System User Manual

Page 181

Advertising
background image

Rev. 5

163

Appendix

Power Supply Details

Insulation coordination

Input

Installation Category II

Overvoltage Category II

Output

Installation Category II

Overvoltage Category II

Pollution degree

2

OUTPUT CHARACTERISTICS

1

NOTE 1 - Output characteristics are for a single standalone unit.

Type of stabilizer

Voltage-current, 4-quadrant

Switch mode

Switching frequency

100 KHz

Output Stage

Source adjustment
range

Voltage

-6 V to +6 V

0 to 50°C

Current

-125 A to +125 A

Sink adjustment range

Voltage

-6 V to +6 V

0 to 50°C, recuperated energy is returned to
line

Current

-125 A to +125 A

Voltage stabilization
(voltage mode)

Source effect

±3 mV

Min-max input voltage

Load effect

±6 mV

0-100% load current

Time effect (drift)

±3 mV

0.5 through 24 hours

Temperature

±3 mV/°C

0 to 50°C

Ripple and noise

±120 mV p-p

Includes switching noise

Error sensing

0.1 V per wire

Above rated output

Transient recovery in
voltage mode

Maximum excursion

±300 mV

Nominal voltage, 50% load step

Recovery time

200

μ

sec

Return within 0.1% of set voltage

Isolation

Voltage

100 V

Output to ground

Parallel operation

Master/slave

Maximum of 2 identical units.

Output Stage Protection

Output overvoltage/overcurrent

Recover by setting input power circuit
breaker to off, then on

Input Stage Protection (PFC)

Internal fault

Recover by setting input power circuit
breaker to off, then on

Input circuit breaker overcurrent

Trips circuit breaker to shut off unit

Small signal
Bandwidth

Voltage channel

2 kHz minimum

Into nominal resistive load 10% of rating

Current channel

800 Hz minimum

Into short circuit, 10% of rating

Rise/Fall time

Voltage channel

250/250

μ

Sec

Into nominal resistive load, measured from
10 to 90%, from 0 to ±100% of rating

Current channel

0.5/0.5 mSec

Into short circuit, measured from 10 to 90%,
from 0 to ±100% of rating

GENERAL (ENVIRONMENTAL) CHARACTERISTICS

Temperature

Operating

0 to +50°C

Full rated load

Storage

-20 to +85°C

Cooling

Two internal fans

Exhaust to the rear

Humidity

0 to 95% RH

Non-condensing

Shock

20 g 11 mS ±50% half sine

Non-operating

Vibration

5-10 Hz:

10 mm double amplitude

3 axes, non-operating

10-55 Hz:

2 g

Table A-13.

Model 4Q06125PS Electrical Specifications (Continued)

Specification

Rating / Description

Condition

Advertising