General Principles

The advanced audio settings are presented on each page as a table:

In the table, the information is organized as follows:

The rows correspond to the audio mono channels of the A/V material stored on the
EVS server. The number of rows depends on the value assigned to the Number of
tracks
setting defined in the Audio settings field group.

The columns correspond to the record channels or play channels.

The values in the cells show the rooting of the audio mono channels:

from the source to the material stored on the EVS server (audio inputs)

from the material stored on the EVS server to the play channels (audio outputs)

The values in the cells of the table, for example 'E1-01', are made up as follows:

The first letter refers to the audio type (E for embedded, D for digital, A for analog, DY
for Dolby Digital, EY for Dolby Embedded).

The first number before the hyphen refers to the play or record channel.

The figure after the hyphen refers to the audio mono channel.