VEGABAR 20

1)

Relating to the nominal measuring range.

2)

In the compensated temperature range of 0°C … +80°C, reference temperature 20°C.

3)

Acc. to IEC 770, point 6.1.2 relating to the nominal measuring range.

Product description

Measuring accuracy (similar to DIN 16 086, DIN V 19 259 - 1 and IEC 770)

Deviation

Reference conditions (acc. to IEC 770)
- temperature

18°C … 30°C rel. humidity

- air pressure

860 kPa … 1060 kPa

Determination of characteristics

limit point adjustment acc. to DIN 16 086

Characteristics

linear

Deviation in characteristics

1)

- accuracy class 0,25

< 0,25 %

- accuracy class 0,1

< 0,1 %

Hysteresis

1)

< 0,02 %

Repeatability

1)

< 0,02 %

Influence of the ambient temperature

Average temperature coefficient
of the zero signal

1) 2)

- accuracy class 0,25

< 0,15 %/10 K

- accuracy class 0,1

< 0,05 %/10 K

Long-term stability

Long-term drift of the zero signal

1) 3)

< 0,1 %

Other actuating variables

Calibration position

standing, diaphragm points downwards

Influence of the installation position

< 0,2 mbar

Vibration resistance

mechanical vibrations with 4 g and

5 … 100 Hz, tested acc. to the regulations of
German Lloyd GL-characteristics 2

Operating conditions

Product

Aggregate conditions

gas, steam, liquid up to high viscosity

also abrasive and aggressive with suitable
material selection of wetted parts
acc. to order code

Ambient conditions

Ambient temperature

-40°C … +85°C

- indicating module

-20°C … +70°C

Storage and transport temperature

-40°C … +85°C

Product temperature

-40°C … +100°C