VEGA VEGASWING 83A EXD User Manual

Page 8

Advertising
background image

8

VEGASWING 81A EXD and 83A EXD

Approvals VEGASWING 80A EXD

WHG

Approval as overfill protection acc. to WHG applied

Recurring test acc. to WHG

According to the type approval to WHG (Z-65.11-154 applied), the recurring test acc. to
WHG can be carried out by pushing the test key on the VEGA TOR 536 EX, 537 EX, 636 EX
signal conditioning instrument. The sensor must be neither removed, nor response must be
triggered by filling the vessel- This is valid for VEGASWING 81A EXD and 83A EXD with
two-wire oscillator SWING E82 Z EX.

Explosion protection VEGASWING 81A EXD, 83A EXD

Certificate

EC-type approval acc. to A TEX 100 a

Classification

ATEX II 2G EEx d IIC T6

Permissible application area

Ex Zone 1

Ambient temperature dependent on
temperature class and Ex-Zone:

see EC-type approval certificate

Electrical safety relevant
characteristics:

see EC-type approval certificate

Oscillator

C - Non-contact switch (SWING E82 C)

Supply voltage

20 … 250 V AC, 50/60 Hz or 20 … 250 V DC

Output

non-contact switch

Current consumption

approx. 3 mA (via load circuit)

Load current

min. 10 mA
max. 400 mA (at I > 300 mA the ambient
temperature can be max. 60°C)
max. 4 A up to 40 ms (not WHG specified)

Protection class

I

Overvoltage category

III

Modes

A: max. detection, overfill protection
B: min. detection, dry run protection

Product description

Advertising