VEGASON 54K … 56K

< 100 mm

Mounting and installation

Correct and wrong length of socket piece

Reference plane

<

100 mm

Wrong

Mounting on a vessel with parabolic tank top

Correct

~

1

/

2

vessel
radius

Wrong

Parabolic effects of rounded or arched
vessel tops

Round or parabolic tank tops act like a para-
bolic mirror for the signals. If the sensor is
placed at the focal point of such a parabolic
tank top, the sensor receives amplified false
echoes. The optimum location is generally in
the area of half the vessel radius from the
centre.

Socket piece too long

If the sensor is mounted in a socket exten-
sion that is too long, strong false echoes are
caused, and measurement is hindered. Make
sure that the transducer protrudes at least
30 mm out of the socket piece.