8

VEGASON 54K … 56K

2.4 Configuration of measuring sys-

tems

A measuring system consists of a sensor
with a 4 … 20 mA signal output and a module
that evaluates and further processes the
level-proportional current signal.

On the following pages you will find instru-
ment configurations designated as measur-
ing systems, several of which are shown with
signal conditioning units.

2.3 Approvals

When using ultrasonic sensors in Ex areas or
in marine applications, the instruments must
be suitable and approved for the explosion
zones and application areas.
The suitability is tested by approval authori-
ties and is certified in approval documents.

VEGASON 50 ultrasonic sensors are ap-
proved for Ex zone 1, 10, 11, 21 and 22.
Please note the attached approval docu-
ments when using a sensor in Ex area.

Types and versions

2.2 Type code

VEGASON 54 P EX.XX X X X X X X X

K -

Plastic housing PBT, M20 x 1.5 cable entry

N -

Plastic housing PBT, ½ NPT cable entry

A -

Aluminium housing, M20 x 1.5 cable entry

FEP - Version A, flange DN 200 (PP)
FEA - Version A, flange DN 200 (Aluminium)
FLP - Version A, flange 8“ (PP)
FLA - Version A, flange 8“ (Aluminium)
SAS - Version B, flange swivelling holder DN 50
SBS - Version B, flange swivelling holder DN 80
GAS - Version C, flange swivelling holder DN 50
GBS - Version C, flange swivelling holder DN 80
RGS - Thread G 1 A

X -

without display

A -

with integrated display module

X -

without adjustment module MINICOM

B -

with adjustment module MINICOM (mounted)

A -

Four-wire 20…72 V DC; 20…253 V AC; 4…20 mA

B -

Four-wire 20…72 V DC; 20…253 V AC; 4…20 mA, HART

®

G -

Profibus PA

.X -

without approval

EXS.X ATEX II 1/2D IP68 TStEx Zone 10

K -

Analogue 4 … 20 mA output signal (two-wire or
four-wire technology)

P -

Profibus

Type 54 - Measuring range 1.0 … 25 m
Type 55 - Measuring range 0.8 … 45 m
Type 56 - Measuring range 1.6 … 70 m

Meas. principle (SON for ultrasonics)