Mounting
Filling
Emptying
Material cone, filling and emptying centered
d
3
1
2
d
10
Filling
Emptying
1 Emptying
2 Filling opening
3 Capacitive
electrode
Material cone, filling centered, emptying laterally
Material cone
When installing the meas. probe in a vessel,
be aware that conical heaps which alter the
switching point can form in solid materials.
We recommend selecting an installation loca-
tion where the electrode detects the average
value of the conical heap.
The measuring probe must be installed in a
way that takes the filling and emptying aper-
tures of the vessel into account. To compen-
sate measurement errors caused by the
conical heap, you should install the electrode
at a distance of approx.
d
/
6
from the vessel
wall.