VEGA VEGAPULS 51K…54K 4 … 20 mA; HART compact sensor User Manual

Page 52

Advertising
background image

52

VEGAPULS 51K … 54K

21750-EN-031222

Technical data

Measuring range

1)

Standard

0 … 20 m

VEGAPULS 54

- DN 50 standpipe

0 … 16 m

- DN 100 standpipe

0 … 19 m

Output signal

Signal output

4 … 20 mA current signal in two-wire or
four-wire technology; the HART

®

signal is

modulated to the 4 … 20 mA signal

Fault signal

current output unchanged, 20.5 mA, 22 mA
(adjustable)

Integration time

0 … 999 seconds (adjustable)

Two-wire technology 4 … 20 mA:
The analogue 4 … 20 mA output signal (measuring signal) is transmitted together with the
power supply via one two-wire cable.

Four-wire technology 4 … 20 mA:
Separate power supply. The analogue 4 … 20 mA output signal (measuring signal) is
transmitted in a cable separate from power supply.

Measured value display (optional)

Liquid crystal indication

- in the sensor

scalable output of measured values as graph
and number

- in the external indicating instrument

powered by the sensor

scalable output of measured values as graph

and number. The display unit can be mounted
up to 25 m away from the sensor

Adjustment

- PC and adjustment software VEGA Visual Operating
- adjustment module MINICOM
- HART

®

handheld

1)

Min. distance of the antenna to the medium 5 cm

Advertising