4 approvals and certificates – VEGA VEGABAR 44 HART User Manual

Page 9

Advertising
background image

VEGABAR 44 (HART

®

)

9

Product description

Operating conditions

Ambient conditions

Ambient temperature

-40°C … +85°C

- with indicating module

-20°C … +70°C

Storage and transport temperature

-40°C … +85°C

Product temperature, dependent on the
seal material of the measuring cell
- Viton

-20°C … +100°C

- EPDM

-40°C … +100°C

- Kalrez

0°C … +100°C

1.4 Approvals and certificates

Approvals

- Ex Zone 2
- StEx Zone 10
- Ship approval
- CENELEC EEx ia IIC
- ATEX II 1G EEx ia IIC
- ATEX II 2G EExd ia IIC

If the use of approved instruments is required for certain applications, the relevant official
documents (test reports, test certificates and conformity certificates) must be observed.
These are supplied with the respective instrument.

CE conformity

VEGABAR 40 corresponds to the requirements of EMC (89/336/EWG) and NSR
(73/23/EWG). Conformity has been judged acc. to the following standards:
EMC

Emission

EN 50 081 - 1: 1992

Susceptibility

EN 50 082 - 2: 1995

NSR

EN 61 010 - 1: 1993

NAMUR regulations

Full compliance with the NAMUR regulations NE 21 and NE 43.

Advertising