VEGATRENN 544 Ex

Product description

Voltage output

Number

1 output

Function

analogue output of processing results

Range

0/2 … 10 V

Current

max. 1 mA

Resolution

0,05 % of range

Linearity error

0,05 % of range

Temperature error

0,06 %/10 k of range

Fail safe relay

Contact

1 floating spdt

AgNiO and hard gold plated

Turn-on voltage

min. 10 mV DC
max. 250 V AC/DC

Switching current

min. 10

µ

A

max. 3 A AC, 1 A DC

Breaking capacity

max. 500 VA, 54 W

DISBUS-output

Function

digital transmission of processing results and
system informations to VEGADIS 174 or

VEGACOM 557

Connection line

2-wire (screened)

Line length

max. 1000 m

Indicating element

LED in front plate

green on: operating voltage on
red: fault signal

Ambient conditions

Permissible ambient temperature

-20

°

C … +60

°

C

Storage and transport temperature

-40

°

C … +80

°

C

Electrical connection

Multiple plug component

to DIN 41 612, series F, 36-pole triple row d, b, z
(partly equipped)

Carrier BGT 596 (Ex)

connection to appropriate module

Housing type 505

connection to screw terminals (max. 2,5 mm

2

)

Electrical protective measures

Protection
- not mounted

IP 00

- mounted in

carrier BGT 596 Ex.M
front completely equipped: IP 40
upper and lower side: IP 20
wiring side: IP 00

- mounted into housing type 505

- terminal side

IP 20

- housing in general

IP 30

Protection class

II (in housing type 505)

Overvoltage category

II

>>

Advertising