4 approvals and certificates – VEGA D96_D97 Profibus PA User Manual

Page 9

Advertising
background image

Pressure transmitter D96/D97 (Profibus PA)

9

Product description

Operating conditions

Ambient conditions

Ambient temperature

-40°C … +85°C

- with indicating module

-20°C … +70°C

Storage and transport temperature

-40°C … +85°C

Pressure transmitter D96

Product temperature
with Viton seal
tube version

-20°C … +85°C

FEP suspension hose

-20°C … +85°C

PE cable

-20°C … +60°C

with EPDM seal

tube version

-40°C … +85°C

FEP suspension hose

-40°C … +85°C

PE cable

-40°C … +60°C

with Hilfuor seal

tube version

-10°C … +85°C

FEP suspension hose

-10°C … +85°C

PE cable

-10°C … +60°C

with Kalrez seal

tube version

0°C … +85°C

FEP suspension hose

0°C … +85°C

PE cable

0°C … +60°C

Pressure transmitter D97

Product temperature

tube version

-40°C … +85°C

FEP suspension hose

-40°C … +85°C

PE cable

-40°C … +60°C

1.4 Approvals and certificates

Approvals

- Ex Zone 2
- CENELEC EEx ia IIC
- ATEX II 1G EEx ia IIC
If the use of approved instruments is required for certain applications, the appropriate
official documents (test reports, test certificates and conformity certificates) must be ob-
served. These are supplied with the respective instrument.

CE conformity

D96 and D97 pressure transmitters meet the requirements of EMC (89/336/EWG) and NSR
(73/23/EWG). Conformity has been judged acc. to the following standards:
EMC

Emission

EN 50 081 - 1: 1992

Susceptibility

EN 50 082 - 2: 1995

NSR

EN 61 010 - 1: 1993

NAMUR regulations

Full compliance with the NAMUR regulations NE 21, May 1993.

Advertising