6 technical data, 1 technical data – VEGA VEGAFLEX 55P (Profibus PA) User Manual

Page 43

Advertising
background image

VEGAFLEX 55P (Profibus PA)

43

Technical data

6 Technical data

6.1 Technical data

Power supply

Supply voltage

9 … 32 V DC)

(output voltage U

O

of the segment

(depending on segment coupler used)

coupler)

see PA specification, e.g.

- non-Ex

22 V DC (nominal voltage of the segment
coupler) max. 32 sensors on one two-wire
cable

- Ex

13.5 V DC (nominal voltage of the segment
coupler) max. 10 sensors on one two-wire
cable (typically 8 sensors)

Current consumption

constantly 10 mA (no leakage current output)

Load

depending on segment coupler, see
technical data of the segment couplers and
Profibus specification

Measuring range

VEGAFLEX 55

0.1 ... 4 m

Output signal

digital (Profibus)

Two-wire technology:

The digital output signal (measuring signal) is
modulated onto the power supply and further
processed in the PLC or process control room .

Integration time

0 … 999 seconds (adjustable)

Adjustment

- adjustment software VEGA Visual Operating on Master-Class 2 PC
- adjustment module MINICOM in the sensor or in the external instrument (optional)
- process adjustment interface PACTware

TM

(under which VVO runs as a subprogram)

- SIMATIC PDM in conjunction with Electronic Device Description (EDD)

Accuracy

1)

(under reference conditions acc. to IEC 770 - relating to the max. measuring range)

Linearity error

< 0.1 %

Temperature drift

0.015 %/10 K

Characteristics

linear

Deviation in characteristics incl.

linearity, reproducibility and
hysteresis (limit point method)

better than 0.05 %

Average temperature coefficient of the
zero signal

0.06 %/10 K

General resolution

max. 1 mm

Resolution of the output signal

0.005 % or 1 mm

1)

ISimilar to DIN 16 086, reference conditions acc. to IEC 770, e.g.
temperature 15°C … 35°C; moisture 45 % … 75 %; pressure 860 mbar … 1060 mbar