3 Product description

VEGACAL 63 • Profibus PA

30028-EN-130917

1

2

3

Fig. 3: Functional principle - Plate capacitor
1 Distance between the electrode surfaces

2 Size of the electrode surfaces

3 Type of dielectric between the electrodes

The probe and the vessel wall are the capacitor plates. The measured

product and the insulation are the dielectric. Due to the higher dielec-

tric constant of the insulation and the conductive product compared to

air, the capacitance increases as the probe is gradually covered.
The capacitance as well as the resistance change are converted by

the electronics module into a level-proportional signal.

Power supply via the Profibus DP/PA segment coupler or VEGALOG

571 EP cards. A two-wire cable according to Profibus specification

serves as carrier of both power and digital data transmission for

multiple sensors. The instrument profile of VEGACAL 63 corresponds

to profile specification version 3.0.
The backlight of the display and adjustment module is powered by the

sensor. Prerequisite is a certain level of operating voltage.
The data for power supply are specified in chapter "Technical data".
The optional heating requires its own operating voltage. You can find

details in the supplementary instructions manual "Heating for display

and adjustment module".
This function is generally not available for approved instruments.

The GSD (instrument master files) and bitmap files necessary for

planning your Profibus-DP-(PA) communication network are available

from the download section on the VEGA homepage www.vega.com

under "Services - Downloads - Software - Profibus". There you can

also find the appropriate certificates. In a PDM environment, an EDD

(Electronic Device Description) is also required to enable the full

range of sensor functions (also available as a download).A CD with

the appropriate files can be ordered via e-mail under [email protected].

com or by phone from one of the VEGA agencies under the order

number "DRIVER.S".

3.3 Operation

The instrument can be adjusted with the following adjustment media:

With the display and adjustment module

Power supply and bus

communication

GSD/EDD