10 supplement, 1 technical data – VEGA VEGAPULS 61 (≥ 2.0.0 - ≤ 3.8) Profibus PA User Manual

Page 54

Advertising
background image

10 Supplement

10.1 Technical data

General data

316L corresponds to 1.4404 or 1.4435, 304 corresponds to 1.4301

Materials, wetted parts with encapsulated antenna system

-

Threaded fitting G1½ A and 1½ NPT

PVDF

-

Hygienic fitting

Adapter of 316L

-

Antenna

PVDF

-

Seal thread

FKM (Viton)

-

Seal, bolting

FKM (Viton)

Materials, wetted parts with plastic horn antenna

-

Horn antenna

PBT-GF30

-

Focussing lens

PP

-

Adapter flange

PPH

-

Seal, adapter flange

FKM (Viton)

Materials, non-wetted parts

-

Compression flange

PPH

-

Mounting strap

316L

-

Fixing screws, mounting strap

316L

-

Fixing screws, adapter flange

304

-

Housing

Plastic PBT (polyester), Alu die-casting powder-
coated, 316L

-

Seal between housing and housing
cover

NBR (stainless steel housing), silicone (Alu/plastic
housing)

-

Inspection window in housing cover for
PLICSCOM

Polycarbonate (UL-746-C listed)

-

Ground terminal

316Ti/316L

Max. torque, mounting screws - strap on the
sensor housing

4 Nm

Weight depending on process fitting and
housing material

0.7 … 3.4 kg (1.543 … 7.496 lbs)

Output variable

Output signal

digital output signal, format according to IEEE-754

Cycle time

min. 1 s (dependent on the parameter setting)

Sensor address

126 (default setting)

Current value

10 mA, ±0.5 mA

Damping (63 % of the input variable)

0 … 999 s, adjustable

Fulfilled NAMUR recommendations

NE

43

54

VEGAPULS

61 • Profibus PA

10 Supplement

28444

-EN

-100426