10 supplement, 1 technical data – VEGA VEGAPULS 61 (≥ 2.0.0 - ≤ 3.8) Profibus PA User Manual
Page 54
10 Supplement
10.1 Technical data
General data
316L corresponds to 1.4404 or 1.4435, 304 corresponds to 1.4301
Materials, wetted parts with encapsulated antenna system
-
Threaded fitting G1½ A and 1½ NPT
PVDF
-
Hygienic fitting
Adapter of 316L
-
Antenna
PVDF
-
Seal thread
FKM (Viton)
-
Seal, bolting
FKM (Viton)
Materials, wetted parts with plastic horn antenna
-
Horn antenna
PBT-GF30
-
Focussing lens
PP
-
Adapter flange
PPH
-
Seal, adapter flange
FKM (Viton)
Materials, non-wetted parts
-
Compression flange
PPH
-
Mounting strap
316L
-
Fixing screws, mounting strap
316L
-
Fixing screws, adapter flange
304
-
Housing
Plastic PBT (polyester), Alu die-casting powder-
coated, 316L
-
Seal between housing and housing
cover
NBR (stainless steel housing), silicone (Alu/plastic
housing)
-
Inspection window in housing cover for
PLICSCOM
Polycarbonate (UL-746-C listed)
-
Ground terminal
316Ti/316L
Max. torque, mounting screws - strap on the
sensor housing
4 Nm
Weight depending on process fitting and
housing material
0.7 … 3.4 kg (1.543 … 7.496 lbs)
Output variable
Output signal
digital output signal, format according to IEEE-754
Cycle time
min. 1 s (dependent on the parameter setting)
Sensor address
126 (default setting)
Current value
10 mA, ±0.5 mA
Damping (63 % of the input variable)
0 … 999 s, adjustable
Fulfilled NAMUR recommendations
NE
43
54
VEGAPULS
61 • Profibus PA
10 Supplement
28444
-EN
-100426