Service, Info – VEGA VEGAPULS 65 (≥ 2.0.0 - ≤ 3.8) Foundation Fieldbus User Manual
Page 38
Advertising
Service
4
Basic adjustment
Display
Diagnostics
▶
Service
Info
4.1
Gating out of false signals
Change now?
4.2
Extended setting
None
4.4
Simulation
Start simulation?
▼
4.4
Reset
Reset now?
4.7
Unit of measurement
m(d)
▼
4.8
Language
Deutsch
▼
4.7
Copy sensor data
Copy sensor data?
4.8
PIN
Enable?
Info
5
Basic adjustment
Display
Diagnostics
Service
▶
Info
5.1
Sensor type
Serial number
12345678
5.2
Date of manufacture
21. January 2009
Software version
3.50
5.3
Last change using PC
21. January 2009
5.4
Sensor characteristics
Display now?
38
VEGAPULS
65 • Foundation Fieldbus
6 Set up with the indicating and adjustment module PLICSCOM
28452
-EN
-090305
Advertising