Vessel pressure

-

Screwed part PVDF

-100 … 300 kPa/-1 … 3 bar (-14.5 … 43.5 psig)

-

Screwed part and flange 316L

-100 … 1600 kPa/-1 … 16 bar (-14.5 … 232 psig)

Process temperature (measured on the process fitting)

-

Process fitting, thread PVDF

-40 … +130 °C (-40 … +266 °F)

-

Other process fittings

-40 … +150 °C (-40 … +302 °F)

Vibration resistance

mechanical vibrations with 4 g and 5 … 100 Hz

7)

Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar

Cable entry/plug

8)

-

Single chamber housing

l

1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5

or:

l

1 x closing cap M20 x 1.5; 1 x blind stopper
M

20 x 1.5

or:

l

1 x closing cap ½ NPT, 1 x blind plug ½ NPT

or:

l

1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5

-

Double chamber housing

l

1 x cable entry M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5; 1 x blind stopper
M

16 x 1.5 or optionally available with 1 x plug

M

12 x 1 for VEGADIS 61

or:

l

1 x closing cap ½ NPT, 1 x blind stopper
½ NPT

, 1 x blind stopper M16 x 1.5 or

optionally 1 x plug M12 x 1 for VEGADIS 61

or:

l

1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5; 1 x blind stopper M16 x 1.5
or optionally available with 1 x plug M12 x 1 for
VEGADIS

61

Spring-loaded terminals for wire cross-sec-
tion

> 2

.5 mm² (AWG 14)

7)

Tested according to the regulations of German Lloyd, GL directive 2.

8)

Depending on the version M12 x 1, according to DIN 43650, Harting, 7/
8" FF.