VEGA VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) Profibus PA User Manual
Page 13
1
3
2
100%
0%
4
Fig. 3: Measuring range (operating range) and max. measuring distance
1
full
2
empty (max. measuring distance)
3
Measuring range
4
Reference plane
The emitted radar impulses of VEGAPULS 63 are electromagnetic
waves. The polarisation plane is the direction of the electrical share.
Their position is marked on the instrument.
1
Fig. 4: Position of the polarisation plane of VEGAPULS 63
1
Marking hole
Make sure that all parts of the instrument exposed to the process, in
particular the sensor element, process seal and process fitting, are
suitable for the existing process conditions. These include above all
the process pressure, process temperature as well as the chemical
properties of the medium.
You can find the specifications in chapter "Technical data" and on the
type label.
Polarisation plane
Suitability for the pro-
cess conditions
VEGAPULS
63 • Profibus PA
13
4 Mounting
28446
-EN
-120530