2 mounting preparations – horn antenna, 2 mounting preparations - horn antenna – VEGA VEGAPULS 62 (≥ 2.0.0 - ≤ 3.8) Profibus PA User Manual
Page 14
You can find the specifications in chapter "Technical data" in the or on
the type label.
4.2 Mounting preparations - Horn antenna
Information:
This information applies only to special versions!
VEGAPULS
62 is also available in versions where the antenna has a
bigger diameter than the process fitting (thread, flange). The antenna
must therefore be disconnected from the process fitting before
mounting. Proceed as follows:
1
Loosen the hexagon screws (3) on the antenna socket with an
Allen wrench (size 3)
2
Remove the antenna (4)
Note:
The plastic conemust not be pulled out of the antenna socket.
3
Insert the antenna from below into the vessel socket and secure it
against falling off
4
Retighten the antenna with hexagon screws to the antenna socket;
torque max. 10 Nm (7.5 lbf ft)
14
VEGAPULS
62 • Profibus PA
4 Mounting
28445
-EN