VEGA VEGAPULS 62 (≥ 2.0.0 - ≤ 3.8) Profibus PA User Manual

Page 56

Advertising
background image

-

Average power

<

25 µW

-

Average power with 1 m distance

<

1 µW/cm

2

Measuring accuracy

Resolution, general

<

1 mm (0.039 in)

Deviation

7)

see diagrams

0,5 m (1.6 ft)

30 m (98.43 ft)

10 mm (0.394 in)

3 mm (0.116 in)

- 3 mm (- 0.116 in)

- 10 mm (- 0.394 in)

0

Fig. 37: Deviation VEGAPULS 62 with horn antenna

2,0 m

(6.562 ft)

30 m

(98.43 ft)

40 mm (1.574 in)

15 mm (0.590 in)

- 15 mm (- 0.590 in)

- 40 mm (- 1.574 in)

0

Fig. 38: Deviation VEGAPULS 62 with horn antenna and increased sensitivity

7)

Incl. non-linearity, hysteresis and non-repeatability.

56

VEGAPULS

62 • Profibus PA

10 Supplement

28445

-EN

-090305

Advertising