Distance d
(m)

10°

30

1.0

2.1

3.2

4.2

5.3

35

1.2

2.4

3.7

4.9

6.2

40

1.4

2.8

4.2

5.6

7.1

45

1.6

3.1

4.7

6.3

7.9

50

1.7

3.5

5.3

7

8.8

55

1.9

3.8

5.8

7.7

9.7

60

2.1

4.2

6.3

8.4

10.6

65

2.3

4.5

6.8

9.1

11.5

70

2.4

4.9

7.4

9.8

12.3

Example:

In a vessel 20 m high, the installation position of the sensor is 1.4 m
from the vessel centre.

The necessary angle of inclination of 4° can be read out from this
chart.

Proceed as follows to adjust the angle of inclination with the swivelling
holder:

1

Loosen terminal screw of the swivelling holder with a fork spanner
SW

13

2

Direct the sensor, check angle of inclination

Information:
The max. angle of inclination of the swivelling holder is approx. 15°

3

Tighten the terminal screw, torque max. 20 Nm.

Information:
The hexagon screws must not be loosened.

Mounting should not be too close to the inflowing material as the
microwave signal will be interferred. The optimum mounting position is
on the opposite of the filling. To avoid strong pollution, the distance to
the filter or dust extraction must be as big as possible.