background image

more than 1 m (3.281 in) length, you must secure the probe by
fastening a suitable isolated brace or guy directly above the end of the
rod.

If there is a danger of the probe touching the vessel wall during
operation due to product movements or agitators etc., the measuring
probe should be securely fixed.

In the gravity weight there is a thread (M12), e.g. for a ring bolt
(optional) - (article no. 2.27424).

Make sure that the probe cable is not completely taut. Avoid tensile
loads on the cable.

Avoid undefined cable-vessel connections, i.e. the connection must be
either grounded reliably or isolated reliably. Any deviation from this
requirement can lead to measurement errors.

Fixing

14

VEGAFLEX

67 • Profibus PA

4 Mounting