VEGA VEGAFLEX 65 4 … 20 mA_HART two-wire User Manual

Page 12

Advertising
background image

I

n vessels with conical bottom it can be advantageous to mount the

sensor in the center of the vessel, as measurement is then possible
down to the lowest point of the vessel bottom.

Fig. 3: Vessel with conical bottom

M

ake sure that the probe is not subjected to strong lateral forces.

M

ount VEGAFLEX 65 at a position in the vessel where no

disturbances, e.g. from filling openings, agitators, etc., can occur.

Fig. 4: Lateral load

E

xtreme vibration caused by the system, e.g. due to agitators or

turbulence in the vessel from inflowing medium, can cause the coax
probe of VEGAFLEX 65 to vibrate in resonance. With coax probes of

Inflowing medium

12

VEGAFLEX

65 • 4 … 20

mA/HART - two-wire

4 M

ounting

31845

-EN

-120329

Advertising