L

0

-2 mm (-0.079

")

2 mm (0.079

")

10 mm (0.394

")

5 mm (0.197

")

-5 mm (-0.197

")

0,15 m (5.906

"

)

0,1 m (3.937

"

)

0,15 m

(5.906

")

0,1 m

(3.937

")

1

1

Fig. 22: Deviation VEGAFLEX 65 in coax version in oil

1

Dead zone - no measurement possible in this area

L

Probe length

Influence of the ambient temperature to the sensor electronics

T

emperature drift

0.03 %/10 K

relating to the max. measuring range

or max. 0.3 %

T

emperature drift - Digital output

3

mm/10 K relating to the max. measuring range or

max. 10 mm

Ambient conditions

A

mbient, storage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions

P

rocess pressure

-1 … +40

bar/-100 … +4000 kPa (-

-14.5 … +580

psig), depending on the process

tting

P

rocess temperature (thread or flange tem-

perature)

-

FKM (V

iton)

-40 … +150 °C (-40 … +302 °F)

-

EPDM

-40 … +150 °C (-40 … +302 °F)

-

FFKM (K

alrez 6375)

-20 … +150 °C (-4 … +302 °F)

T

he measurement error from the process condi-

tions is in the specified pressure and temperature
range of below 1 %.

VEGAFLEX

65 • 4 … 20

mA/HART - two-wire

45