VEGA VEGABAR 63 Foundation Fieldbus User Manual

Page 53

Advertising
background image

-

Connection between IP 68 transmitter
and external electronics housing

PUR, FEP, PE

-

Type plate support with IP 68 version on
cable

PE hard

Weight approx.

0.8 kg (1.764 lbs)

Output variable

Output

-

Signal

digital output signal, Foundation Fieldbus protocol

-

Physical layer

according to IEC 61158-2

Channel Numbers

-

Channel 1

Primary Value

-

Channel 2

Secondary Value 1

-

Channel 3

Secondary Value 2

-

Channel 4

Temperature Value

Transmission rate

31.25 Kbit/s

Current value

10 mA, ±0.5 mA

Dynamic behaviour output

Run-up time approx.

10 s

90 %

100 %

10 %

t

t

T

A

t

t

S

2

1

Fig. 28: Sudden change of the process variable, dead time t

T

, rise time t

A

and step response time t

S

1

Process variable

2

Output signal

Dead time

150 ms

Rise time

100 ms (10 … 90 %)

Step response time

250 ms (ti: 0 s, 10 … 90 %)

Damping (63 % of the input variable)

0 … 999 s, adjustable

VEGABAR

63 • Foundation Fieldbus

53

10 Supplement

32464

-

EN