Rod: ø 16 mm (0.63 in)

approx. 1600 g/m (17 oz/ft)

-

Cable: ø 6 mm (0.236 in)

approx. 170 g/m (1.8 oz/ft)

-

Gravity weight

approx. 730 g (25.8 oz)

Probe length L (from seal surface)

-

Tube: ø 43 mm (1.693 in)

up to 6 m (19.69 ft)

-

Trimming accuracy - tube

<

1 mm (0.039 in)

-

Rod: ø 16 mm (0.63 in)

up to 6 m (19.69 ft)

-

Trimming accuracy - rod

<

1 mm (0.039 in)

-

Cable: ø 6 mm (0.236 in)

up to 60 m (196.9 ft)

-

Trimming accuracy - cable

±

0.05 %

Max. tensile load with cable: ø 6 mm
(

0.236 in)

10 KN (2248 lbf)

Lateral load

-

Tube: ø 43 mm (1.693 in)

100 Nm (74 lbf ft)

-

Rod: ø 16 mm (0.63 in)

30 Nm (22 lbf ft)

Input variable

Measured variable

Level of liquids

Min. dielectric figure (lower medium)

by 10 higher than the ε

r

of the upper medium

Min. layer thickness (upper medium)

>

100 mm (3.9 in)

The measured value deviates from the actual level
until the min. layer thickness is reached.

Max. layer thickness (upper medium)

-

Dielectric figure (upper medium) 10

6 m (19.69 ft)

-

Dielectric figure (upper medium) 5

10 m (32.81 in)

-

Dielectric figure (upper medium) 2

20 m (65.61 in)

Min. dielectric figure (upper medium) - coax
version

ε

r

>

1.4

VEGAFLEX

67 • Foundation Fieldbus

41

10 Supplement

32314

-

EN

-120329