background image

Length HF connection cable to
external housing

2, 5 oder 10 m (6.562, 16.4, 32.81 ft)

Min. dielectric figure of the medium

-

VEGAFLEX

61, 62, 63, 65

ε

r

>

1.6

-

if sensor length L > cable
length HF connection cable

ε

r

>

2

Process conditions

Process pressure

depending on the process fitting

Ambient temperature - HF con-
nection cable

-40 … +85 °C (-40 … +185 °F)

Ambient, storage and transport temperature on the instrument housing

-

without indicating and adjust-
ment module

-40 … +80 °C (-40 … +176 °F)

-

with indicating and adjustment
module

-20 … +70 °C (-4 … +158 °F)

Electromechanical data

Cable entry/plug

1)

-

Instrument housing

l

1 x cable gland M20 x 1.5 (cable:
ø

6 … 12 mm), 2 x blind stopper

M

20 x 1.5

or:

l

1 x closing cap ½ NPT, 2 x blind
stopper ½ NPT

or:

l

1 x plug (depending on the version),
2 x blind plugs M20 x 1.5

-

Housing socket

l

1 x N-socket

-

Sensor housing

l

1 x N-socket

Spring-loaded terminals

for wire cross-section up to 2.5 mm²
(AWG 14)

Electrical protective measures

Protection

-

Sensor housing

IP

66/IP 68 (1 bar)

-

Instrument housing - Instru-
ment socket

IP

66/IP 67

1)

Depending on the version M12 x 1, according to DIN 43650, Harting, Am-
phenol-Tuchel, 7/8" FF.