background image

Linearisation curve

Linear

Enter the requested parameters via the appropriate keys, save your
settings and jump to the next menu item with the [->] key.

Caution:
Note the following if the VEGAFLEX 65 with corresponding approval is
used as part of an overfill protection system according to WHG (Water
Resources Act):

If a linearisation curve is selected, the measuring signal is no longer
compulsorily linear proportional to the level. This must be taken into
consideration by the user, particularly when adjusting the switching
point on the level switch.

In this menu item you can enter an unambiguous designation for the
sensor, e.g. the measurement loop name or the tank or product
designation. In digital systems and in the documentation of larger
plants, a singular designation should be entered for exact identification
of individual measuring points.

Sensor-TAG

Sensor

With this menu item, the Basic adjustment is finished and you can now
jump to the main menu with the [ESC] key.

This function enables reading out parameter adjustment data as well
as writing parameter adjustment data into the sensor via the indicating
and adjustment module. A description of the function is available in the
operating instructions manual "Indicating and adjustment module".

The following data are read out or written with this function:

l

Measured value presentation

l

Adjustment

l

Medium

l

Vessel form

l

Damping

l

Linearisation curve

l

Sensor-TAG

l

Displayed value

l

Unit of measurement

l

Language

l

Sensitivity

Sensor-TAG

Copy sensor data