9 Supplement
VEGACAP 35 • - Relay (DPDT)
33759-EN-130916
Ʋ Max.
3 A AC, 1 A DC
Breaking capacity
Ʋ Min.
50 mW
Ʋ Max.
750 VA AC, 54 W DC
If inductive loads or stronger currents are switched
through, the gold plating on the relay contact surface will
be permanently damaged. The contact is then no longer
suitable for switching low-level signal circuits.
Potential separation
> 500 V DC
Contact material (relay contacts)
AgNi (Au plated) or AgSnO (Au plated)
Modes (switchable)
A (overfill protection)/B (dry run protection)
Switching delay
Ʋ When immersed
0.7 s
Ʋ When laid bare
0.7 s
Ʋ In case of failure
1 s
Ambient conditions
Ambient temperature on the housing
-40 … +80 °C (-40 … +176 °F)
Storage and transport temperature
-40 … +80 °C (-40 … +176 °F)
Process conditions
Process pressure
-1 … 16 bar/-100 … 1600 kPa (-14.5 … 232 psig)
See following diagram
Process temperature
See following diagram
16 bar
(232psi)
-30°C
(-22°F)
80°C
(176°F)
60°C
(140°F)
0°C
(32°F)
2
1
Fig. 25: Process pressure - Process temperature - VEGACAP 35 with process fitting of Aluminium
1 Process pressure