VEGA VEGACAP 35 - Relay (DPDT) User Manual

Page 28

Advertising
background image

28

9 Supplement

VEGACAP 35 • - Relay (DPDT)

33759-EN-130916

Ʋ Max.

3 A AC, 1 A DC

Breaking capacity

Ʋ Min.

50 mW

Ʋ Max.

750 VA AC, 54 W DC
If inductive loads or stronger currents are switched

through, the gold plating on the relay contact surface will

be permanently damaged. The contact is then no longer

suitable for switching low-level signal circuits.

Potential separation

> 500 V DC

Contact material (relay contacts)

AgNi (Au plated) or AgSnO (Au plated)

Modes (switchable)

A (overfill protection)/B (dry run protection)

Switching delay

Ʋ When immersed

0.7 s

Ʋ When laid bare

0.7 s

Ʋ In case of failure

1 s

Ambient conditions
Ambient temperature on the housing

-40 … +80 °C (-40 … +176 °F)

Storage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions
Process pressure

-1 … 16 bar/-100 … 1600 kPa (-14.5 … 232 psig)
See following diagram

Process temperature

See following diagram

16 bar

(232psi)

-30°C

(-22°F)

80°C

(176°F)

60°C

(140°F)

0°C

(32°F)

2

1

Fig. 25: Process pressure - Process temperature - VEGACAP 35 with process fitting of Aluminium
1 Process pressure

2 Process temperature

Advertising