VEGA VEGACAP 35 - Relay (DPDT) User Manual
Page 29
29
9 Supplement
VEGACAP 35 • - Relay (DPDT)
33759-EN-130916
16 bar
(232psi)
-10°C
(-4°F)
80°C
(176°F)
60°C
(140°F)
0°C
(32°F)
2
1
Fig. 26: Process pressure - Process temperature - VEGACAP 35 with process fitting of 316L
1 Process pressure
2 Process temperature
16 bar
(232psi)
-30°C
(-22°F)
80°C
(176°F)
60°C
(140°F)
0°C
(32°F)
2
1
Fig. 27: Process pressure - Process temperature - VEGACAP 35 with process fitting of 316Ti
1 Process pressure
2 Process temperature
Dielectric constant
≥ 1.5
Electromechanical data
Cable entry/plug (dependent on the version)
Ʋ Single chamber housing
– 1 x cable entry M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind plug M20 x 1.5; attached 1 x cable entry
M20 x 1.5
or:
– 1 x cable entry ½ NPT, 1 x blind plug ½ NPT, 1 x cable
entry ½ NPT
or:
– 1 x plug M12 x 1; 1 x blind plug M20 x 1.5
Screw terminals
for wire cross-section up to 1.5 mm² (AWG 16)
Adjustment elements
Mode switch
Ʋ A
Min. detection or dry run protection
Ʋ B
Max. detection or overflow protection