7 maintenance and fault rectification, 1 maintenance, 2 electronics exchange – VEGA VEGAKON 61 - Relay (DPDT) User Manual

Page 16: 7maintenance and fault rectification

Advertising
background image

7

Maintenance and fault rectification

7

.1 Maintenance

When used as directed in normal operation, VEGAKON 61 is
completely maintenance free.

7

.2 Electronics exchange

In general, all electronics modules of series KONE60 can be
interchanged. If you want to use an electronics module with a different
signal output, you can download the corresponding operating
instructions manual from our homepage under Downloads.

Proceed as follows:

1

Switch off power supply

2

Unscrew the housing cover

3

Loosen compression fittings with a screwdriver

4

Pull the connection cables out of the terminals

5

Loosen the two screws with a screw driver (Phillips recessed
head)

6

Pull out the old electronics module

7

Compare the new electronics module with the old one. The type
label of the electronics module must correspond to that of the old
electronics module.

8

Note settings of all adjustment elements of the old electronics
module.

Set the adjustment elements of the new electronics module to the
same settings of the old one.

9

Screw in and tighten the two holding screws with a screwdriver
(Phillips)

10 Insert the wire ends into the open terminals according to the wiring

plan

11 Tighten the screw terminals
12 Check the hold of the wires in the terminals by lightly pulling on

them

13 Check cable gland on tightness. The seal ring must completely

encircle the cable.

14 Screw the housing cover on

The electronics exchange is now finished.

As soon as you insert the electronics module, VEGAKON 61 is ready
for operation.

16

VEGAKON

61 • - Relay (DPDT)

7 Maintenance and fault rectification

32647

-EN

-100219

Advertising