VEGA VEGAKON 61 - Relay (DPDT) User Manual
Page 20
surface will be permanently damaged. The contact
is then no longer suitable for switching low-level
signal circuits.
Contact material (relay contacts)
AgNi or AgSnO and Au plated
Modes (adjustable)
-
A
Max. detection or overflow protection
-
B
Min. detection or dry run protection
Switching delay
-
When immersed
0.5 s
-
When laid bare
0.5 s
Ambient conditions
Ambient temperature on the housing
-40 … +70 °C (-40 … +158 °F)
Ambient temperature with operating voltage
>
60 V DC
-40 … +50 °C (-40 … +122 °F)
Storage and transport temperature
-40 … +80 °C (-40 … +176 °F)
Process conditions
Permissible process temperature
-
Without temperature adapter
-40 … +100 °C (-40 … +212 °F)
-
with temperature adapter
-40 … +150 °C (-40 … +302 °F)
1
2
110 °C
(230 °F)
120 °C
(248 °F)
100 °C
(212 °F)
130 °C
(266 °F)
140 °C
(284 °F)
150 °C
(302 °F)
50 °C
(122 °F)
60 °C
(140 °F)
70 °C
(158 °F)
Fig. 21: Ambient temperature - Process temperature
1
Process temperature in °C
2
Ambient temperature in °C
Process pressure
-1 … 25 bar/-100 … 2500 kPa (-14.5 … 362 psig)
Conductive of the medium
min. 7.5 µS/cm
20
VEGAKON
61 • - Relay (DPDT)
9 Supplement
32647
-EN
-100219