1
2
0 °C
(32 °F)
0 bar
(0 psi)
50 °C
(122 °F)
10 bar
(50 psi)
20 bar
(290 psi)
25 bar
(363 psi)
-40 °C
(-40 °F)
100 °C
(212 °F)
150 °C
(302 °F)
Fig. 22: Process temperature - Process pressure
1
Process temperature in °C
2
Process pressure in bar
Electromechanical data
Cable gland
-
with relay module
1 x cable entry M20 x 1.5; 1 x blind stopper
M
20 x 1.5 (cable gland M20 x 1.5 is attached)
Screw terminals
for wire cross-section up to 1.5 mm² (AWG 16)
Voltage supply
Operating voltage
20 … 253 V AC, 50/60 Hz, 20 … 72 V DC (at
U >
60 V DC, the ambient temperature can be max.
50 °C/122 °F)
Power consumption
1 … 8 VA (AC), approximately 1.3 W (DC)
Electrical protective measures
Protection rating
IP
66
Overvoltage category
III
Protection class
I
VEGAKON
61 • - Relay (DPDT)
21
9 Supplement
32647
-
EN
-100219