2

0 °C

(32 °F)

0 bar

(0 psi)

50 °C

(122 °F)

10 bar

(50 psi)

20 bar

(290 psi)

25 bar

(363 psi)

-40 °C

(-40 °F)

100 °C

(212 °F)

150 °C

(302 °F)

Fig. 22: Process temperature - Process pressure

1

Process temperature in °C

2

Process pressure in bar

Electromechanical data

Cable gland

-

with relay module

1 x cable entry M20 x 1.5; 1 x blind stopper
M

20 x 1.5 (cable gland M20 x 1.5 is attached)

Screw terminals

for wire cross-section up to 1.5 mm² (AWG 16)

Voltage supply

Operating voltage

20 … 253 V AC, 50/60 Hz, 20 … 72 V DC (at
U >

60 V DC, the ambient temperature can be max.

50 °C/122 °F)

Power consumption

1 … 8 VA (AC), approximately 1.3 W (DC)

Electrical protective measures

Protection rating

IP

66

Overvoltage category

III

Protection class

I