9

3 Product description

VEGABAR 55 • Foundation Fieldbus - climate compensated

39443-EN-130321

This operating instructions manual applies to the following instrument

versions:

Software from 3.82

3.2 Principle of operation

The VEGABAR 55 - climate compensated is a pressure transmitter

for use in the chemical, food processing and pharmaceutical industry

under difficult climatic conditions (cold medium and warm humid

environment).
Depending on the version, the pressure transmitter is used for meas-

urement of level, gauge pressure or vacuum. Measured products are

gases, vapours and liquids also with higher temperatures.

Measuring unit is the METEC

®

measuring cell. This measuring cell

consists of the ceramic-capacitive CERTEC

®

absolute pressure

measuring cell and a special temperature-compensated isolating

system. The process pressure causes a capacitance change in the

measuring cell via the ceramic diaphragm. This change is converted

into an electrical signal, compared with an integrated reference pres-

sure measurement and outputted as measured value via the output

signal.
The hydrostatic pressure of the product or the process pressure

causes a capacitance change in the measuring cell via the metallic

process diaphragm and the isolating liquid. This change is converted

into a corresponding output signal.

Power is supplied via the H1 Fieldbus. A two-wire cable according to

Fieldbus specification serves as carrier of both power and digital data

for multiple sensors. This cable can be operated in two versions:

via an H1 interface card in the control system and additional power

supply

via a Linking device with HSE (High speed Ethernet) and addi-

tional power supply according to IEC 61158-2

The DD (Device Descriptions) and CFF (capability files) necessary

for planning and configuration of your FF (Foundation Fieldbus) com-

munication network are available in the download area of the VEGA

homepage www.vega.com under "Services - Downloads - Software

- Foundation Fieldbus". The appropriate certificates are also available

there. A CD with the appropriate files and certificates can be ordered

via e-mail under [email protected] or by phone from one of the

VEGA agencies under the order number "DRIVER.S".
The backlight of the display and adjustment module is powered by the

sensor. Prerequisite is a certain level of operating voltage.
The data for power supply are specified in chapter "Technical data".
The optional heating requires its own operating voltage. You can find

details in the supplementary instructions manual "Heating for display

and adjustment module".
This function is generally not available for approved instruments.

Scope of this operating

instructions manual

Application area

Functional principle

Power supply and bus

communication

DD/CFF