2 dimensions – VEGA VEGAPULS SR 68 4 … 20 mA_HART - four-wire User Manual

Page 71

Advertising
background image

71

11 Supplement

VEGAPULS SR 68 • 4 … 20 mA/HART - four-wire

38295-EN-130624

Integrated clock
Date format

Day.Month.Year

Time format

12 h/24 h

Time zone Ex factory

CET

Measurement electronics temerature
Resolution

1 °C (1.8 °F)

Accuracy

±1 °C (1.8 °F)

Voltage supply
Operating voltage

Ʋ Version for low voltage

9.6 … 48 V DC, 20 … 42 V AC, 50/60 Hz

Ʋ Version for mains voltage

90 … 253 V AC, 50/60 Hz

Interpolation protection

Integrated

Max. power consumption

4 VA; 2.1 W

Electrical protective measures
Protection, depending on housing version

Ʋ Plastic housing

IP 66/IP 67

Ʋ Aluminium housing, stainless steel

housing - investment casting, stain-

less steel housing - electro-polished

IP 66/IP 68 (0.2 bar)

4)

Ʋ Aluminium and stainless housing, in-

vestment casting (optionally available)

IP 66/IP 68 (1 bar)

Overvoltage category

III

Protection class

III

Approvals
Instruments with approvals can have different technical data depending on the version.
For that reason the associated approval documents of these instruments must be carefully noted.

They are part of the delivery or can be downloaded under www.vega.com and "VEGA Tools" as

well as under "Downloads" and "Approvals".

11.2 Dimensions

The following dimensional drawings represent only an extract of all possible versions. Detailed

dimensional drawings can be downloaded at www.vega.com/downloads under "Drawings".

4)

The prerequisites for maintaining the protection rating are a suitable cable as well as correct mounting.

Advertising