VEGA VEGAPULS 62 (≥ 2.0.0 - ≥ 4.0.0) HART and accumulator pack User Manual

Page 66

Advertising
background image

66

11 Supplement

VEGAPULS 62 • HART and accumulator pack

40793-EN-121011

Measurement electronics temerature
Resolution

1 °C (1.8 °F)

Accuracy

±1 °C (1.8 °F)

External battery charger
Mains voltage

100 … 240 V AC

Output voltage

24 V DC

Output current (shortcircuit proof) max. 500 mA
Load current limitation

70 mA

DC plug (inside plus, outside minus)

2.1 mm

Integrated accumulator
Type

Lithium ions

Voltage

14.8 V

Accumulator capacity

4.7 Wh

Charging period from 0 % to 100 %

approx.

4 h

Operating time after 10 min. charging of

0 %

> 3 h

Operating time in mode 4 (sensor per-

manently on) with completely charged

accumulator

> 60 h

Temperature range

Ʋ Charge accumulator

0 … +45° C (+32 … +167 °F)

Ʋ Accumulator operation

-20 … +60° C (-4 … +140 °F)

Temperature derating accumulator capacity

Ʋ +25° C (+77 °F)

100 %

Ʋ -10° C (+14 °F)

50 %

Electrical protective measures
Protection, depending on housing version

Ʋ Plastic housing

IP 66/IP 67

Ʋ Aluminium housing, stainless steel

housing - investment casting, stain-

less steel housing - electro-polished

IP 66/IP 68 (0.2 bar)

6)

Overvoltage category

III

Protection class

III

Approvals
Instruments with approvals can have different technical data depending on the version.
For that reason the associated approval documents of these instruments must be carefully noted.

They are part of the delivery or can be downloaded under www.vega.com and "VEGA Tools" as

well as under "Downloads" and "Approvals".

6)

The prerequisites for maintaining the protection rating are a suitable cable as well as correct mounting.

Advertising