6 maintenance and fault rectification, 1 maintenance, 2 remove interferences – VEGA PLICSMOBILE GSM_GPRS radio module User Manual

Page 19: 6maintenance and fault rectification

Advertising
background image

6

Maintenance and fault rectification

6

.1 Maintenance

If the instrument is used properly, no special maintenance is required
in normal operation.

6

.2 Remove interferences

The operator of the system is responsible for taking suitable measures
to rectify faults.

A maximum of reliability is ensured. Nevertheless, faults can occur

during operation. These may be caused by the following, e.g.:

l

Measured value from sensor not correct

l

Voltage supply

l

Interference on the cables

The first measures to be taken are to check the input/output signals

as well as to evaluate the error messages via the DTM. The procedure
is described below. In many cases, the causes can be determined in
this way and faults can be rectified.

Should these measures not be successful, please call in urgent

cases the VEGA service hotline under the phone no. +49 1805 858550.

The hotline is available to you 7 days a week round-the-clock. Since
we offer this service world-wide, the support is only available in the
English language. The service is free of charge, only the standard
telephone costs will be charged.

?

No indication of the signal strength

l

No GSM network available

à

Check network availability via mobile phone

?

E

008

l

Sensor not found

à

Check connection of the sensor

?

E

013

l

Sensor signals failure, no valid measured value

à

Check sensor parameter adjustment

à

Send sensor for repair

Reaction when malfunc-
tions occur

Failure reasons

Fault rectification

24

hour service hotline

Error messages

PLICSMOBILE • GSM/GPRS radio module

19

6 Maintenance and fault rectification

36849

-EN

-111221

Advertising