.4 Connection steps sensor electronics

These steps must only be carried out if the sensor electronics is to be
powered via an additional voltage supply, for example, if the 4 … 20 mA
signal has to be evaluated.

Proceed as follows:

1

Unscrew housing cover of the upper housing chamber

2

Loosen and isolate the internal connection cable from the
terminals

3

Remove the blind stopper of the upper housing chamber

4

Insert the cable gland which is included in the delivery

5

Carry out connection as described in the operating instructions
manual of the sensor

3

.5 Wiring plan

1

Bus

USB

Status

Test

SIM-Card

1

2

+

( )

(-)

Fig. 3: Connection of the PLICSMOBILE supply voltage

1

Voltage supply

Wiring plan PLICS-
MOBILE