33

5 Connecting to power supply

VEGAPULS 68 • 4 … 20 mA/HART - two-wire

36535-EN-130205

Note:

If an instrument with Ex-d-ia approval is used, HART multidrop ope-

ration is not possible.

4...20mA

2

1

2

+

( )

(-)

1

Fig. 33: Connection compartment, Ex-d double chamber housing
1 Voltage supply, signal output

2 Ground terminal for connection of the cable screen

3

4

1

2

Fig. 34: Top view of the plug connector
1 Pin 1

2 Pin 2

3 Pin 3

4 Pin 4

Contact pin

Colour connection

cable in the sensor

Terminal, electronics

module

Pin 1

Brown

5

Pin 2

White

6

Pin 3

Blue

7

Pin 4

Black

8

5.6 Wiring plan - version IP 66/IP 68, 1 bar

1

2

Fig. 35: Wire assignment fix-connected connection cable
1 brown (+) and blue (-) to power supply or to the processing system

2 Shielding

Connection compartment

Plug M12 x 1 for external

indicating and adjust-

ment unit

Wire assignment, con-

nection cable

Advertising