5 Connecting to the sensor

VEGABOX 03 •

45925-EN-131119

5 Connecting to the sensor

5.1 Preparing the connection

Always keep in mind the following safety instructions:

Connect only in the complete absence of line voltage

If overvoltage surges are expected, overvoltage arresters should

be installed

The sensor is connected with a fix connected cable to the VEGABOX

03. The VEGABOX 03 is connected with standard two-wire cable

without screen to power supply. If electromagnetic interference is

expected which is above the test values of EN 61326-1 for industrial

areas, screened cable should be used.
We generally recommend the use of screened cable for HART multi-

drop mode.
In the product configurator of VEGABOX 03, different cable glands

are available. This selection covers all cable diameters in the range of

4 … 14 mm (0.157 … 0.551 in).
You can find further information on the cable glands under "Technical

data/Electromechanical data"

If screened cable is necessary, connect the cable screen on both

ends to ground potential. In the VEGABOX 03, the screen must be

connected directly to the internal ground terminal. The ground termi-

nal on the outside of the housing must be connected to the potential

equalisation (low impedance).
If potential equalisation currents are expected, the connection on the

processing side must be made via a ceramic capacitor (e. g. 1 nF,

1500 V). The low-frequency potential equalisation currents are thus

suppressed, but the protective effect against high frequency interfer-

ence signals remains.

5.2 Connection procedure

The voltage supply and sensor are connected via the spring-loaded

terminals in the housing of the VEGABOX 03.

Proceed as follows:
1. Unscrew the housing cover
2. Loosen compression nut of the cable glands
3. Remove approx. 7 cm (0.276 in) of the cable mantle, strip approx.

1 cm (0.4 in) of insulation from the ends of the individual wires

4. Insert the sensor and the connection cable into VEGABOX 03

through the cable entry

Safety instructions

Select connection cable

Cable screening and

grounding

Connection technology

Connection procedure