3 wiring plan – VEGA VEGABOX 03 User Manual

Page 14

Advertising
background image

14

5 Connecting to the sensor

VEGABOX 03 •

45925-EN-131119

5.3 Wiring plan

3

2

1

Fig. 8: Terminal compartment VEGABOX 03
1 Spring-loaded terminals for connection of the sensor

2 Release opening

3 Ground terminal for connection of the cable screen

2
3

+

1

-

Fig. 9: Wiring plan VEGABOX 03 for VEGAWELL 52 4 … 20 mA, 4 … 20 mA/

HART
1 To the sensor

2 To power supply or the processing system

3 Shielding

1)

Wire number

Wire colour/Polarity

Terminal

1

brown (+)

1

2

blue (-)

2

Shielding

Grounding

Terminal compartment

Wiring plan - VE-

GAWELL 52 4 … 20 mA,

4 … 20 mA/HART

1)

Connect screen to ground terminal. Connect ground terminal on the outside

of the housing to ground as prescribed. The two terminals are galvanically

connected.