5 blocking valves, 1 blocking valve according to din16270, 5blocking valves – VEGA Mounting accessories, pressure measurement technology User Manual
Page 9
5
Blocking valves
5
.1 Blocking valve according to DIN 16270
Blocking valves according to DIN 16270 enable simple mounting,
setup and dismounting of a pressure transmitter with process fitting
G½.
The ventilation screw enable the removal of residual air as well as a
relieve of the residual pressure between valve and pressure trans-
mitter.
The valve is opened via a hand wheel (turning anticlockwise) or closed
(turning clockwise). The sealing in the medium is made metallically,
the sealing of the valve spindle via a gland packing.
2
1
4
3
1
4
1
1
3
1
2
G ½
G ½
90 mm
(3.54")
100 mm
(3.94")
G ½
DIN EN 837-1
Fig. 3: Configuration of blocking valve according to DIN 16270
1
Input (process)
2
Valve for blocking, process
3
Ventilation screw
4
Output (pressure transmitter)
Application area/Func-
tion
Handling
Configuration
Mounting accessories, pressure measurement technology